Input Voltage.............85-264 VAC Input Current.............1.7A@115VAC, 0.75A@230VAC Input Frequency...........47-63 Hz Inrush Current............30A@115VAC, 60A@230VAC cold start Power Factor..............0.98@115VAC; 0.95@230VAC Output Voltage............See table; ±10% adjustable Overload Protection.......105% to 135% constant current limiting Overvoltage Protection....110% to 135% of output voltage Setup/Rise/Hold-up time...800ms/50ms/20ms Operating Temperature.....0-40°C @100% load, -10°C @80, 60°C @50% Safety Standards..........UL1950, EN60950 EMC Standards.............EN55022 Class B, EN61000-4,2,3,4,5,6,11 EN61000-3-2,3 Connectors................Input: JST/VH, 3-pin/3.96mm pitch Output: JST/VH, 8-pin/3.96mm pitch Weight....................0.88 lb Dimensions, W*L*H.........2.44*8.74*1.38 inches
LPP-100 Series PFC
100W Single Output
Open Frame AC/DC Switchers
- PFC Meets EN 61000-3-2
- High Reliability @ Low Cost
- 85-264 VAC Universal Input
- Built-in EMI Filter
- Low Ripple & Noise
- Overvoltage & Overload Protections
- UL, cUL, TUV, CB & CE Approved
| Model No. | DC Output | Tol. | R & N | Eff. |
| LPP-100-3.3 | 3.3V@20A | ±2% | 100mV | 69% |
| LPP-100-5 | 5V@20A | ±2% | 100mV | 75% |
| LPP-100-7.5 | 7.5V@13.3A | ±2% | 100mV | 76% |
| LPP-100-12 | 12V@8.4A | ±2% | 100mV | 79% |
| LPP-100-13.5 | 13.5V@7.5A | ±2% | 100mV | 79% |
| LPP-100-15 | 15V@6.7A | ±2% | 100mV | 80% |
| LPP-100-24 | 24V@4.2A | ±1% | 150mV | 83% |
| LPP-100-27 | 27V@3.8A | ±1% | 150mV | 83% |
| LPP-100-48 | 48V@2.1A | ±1% | 250mV | 83% |