PU200 Series                                     Data Sheet
200W Single to Quad Output
U-Bracket AC/DC Switchers

Input Voltage.............90-130 VAC or 180-264 VAC auto-ranging
Input Frequency...........47-63 Hz
Inrush Current............20A@115VAC, 40A@230VAC; @25°C cold start
Input-Output Isolation....3,000 VAC
Leakage Current...........0.4mA max. @115VAC/60Hz, 0.8mA max. @230VAC/50Hz
Ripple & Noise............2% peak to peak max.
Overcurrent Protection....Short circuit protectin on all outputs
Overvoltage Protection....112% to 132% on main output
Power Fail Detect Signal..TTL logic high for normal operation,
                          TTL logic low upon loss of input power
Operating Temperature.....0-70°C; 100% load up to 50°C
Derating..................Derated 2.5%/°C from 50°C to 70°C
Hold-up Time..............20 msec min. at nominal input
Switching Frequency.......75KHZ ± 5KHz
Efficiency................70% min. at full load
Line Regulation...........±0.5% max. at full load
Safety Approvals..........UL1950, CSA C22.2 No. 950, TUV EN60950/IEC950
EMI Standards.............FCC Class B, EN55011 (CISPR 11) Level B
MTBF......................>450,000 hours at full load
Input Connector...........3-pin screw terminal block
Output Connector..........13-pin screw terminal block
Weight....................3.1 lb for U-Bracket version
                          3.9 lb for enclosed version
Dimensions, W*L*H.........5*9*2.55 inches

 Model No.

 Output
 Vnom  Imin  Imax  *Ipk *Pmax1 *Pmax2  Tol.

Single Output Models
 PU200-10  5V  3A  40A  ---  150W  200W  ±2%
 PU200-12  12V  1.2A  16.7A  ---  150W  200W  ±2%
 PU200-13  15V  1A  13.4A  ---  150W  200W  ±2%
 PU200-14  24V  0.6A  8.4A  ---  150W  200W  ±2%
 PU200-16  30V  0.5A  6.7A  ---  150W  200W  ±2%
 PU200-18  48V  0.3A  4.2A  ---  150W  200W  ±2%

Dual Output Models
 PU200-23  +5V
 +12V
 3A
 0A
 30A
 8A
 ---
 12A
 150W  200W  ±2%
 ±4%
 PU200-24  +5V
 +15V
 3A
 0A
 30A
 6A
 ---
 9A
 150W  200W  ±2%
 ±4%
 PU200-25  +5V
 +24V
 3A
 0A
 30A
 4A
 ---
 6A
 150W  200W  ±2%
 ±4%

Triple Output Models
 PU200-30  +5V
 +12V
 -5V
 3A
 0A
 0A
 30A
 8A
 6A
 ---
 12A
 ---
 150W  200W  ±2%
 ±4%
 ±4%
 PU200-31  +5V
 +12V
 -12V
 3A
 0A
 0A
 30A
 8A
 4A
 ---
 12A
 ---
 150W  200W  ±2%
 ±4%
 ±4%
 PU200-32  +5V
 +15V
 -15V
 3A
 0A
 0A
 30A
 6A
 4A
 ---
 9A
 ---
 150W  200W  ±2%
 ±4%
 ±4%
 PU200-33  +5V
 +15V
 -12V
 3A
 0A
 0A
 30A
 6A
 4A
 ---
 9A
 ---
 150W  200W  ±2%
 ±4%
 ±4%

Quad Output Models
 PU200-40  +5V
 +12V
 -12V
 
*F5V
 3A
 0A
 0A
 0A
 30A
 8A
 4A
 6A
 ---
 12A
 ---
 ---
 150W  200W  ±2%
 ±4%
 ±4%
 ±4%
 PU200-41  +5V
 +15V
 -15V
 
*F24V
 3A
 0A
 0A
 0A
 30A
 6A
 4A
 4A
 ---
 9A
 ---
 ---
 150W  200W  ±2%
 ±4%
 ±4%
 ±4%
 PU200-42  +5V
 +12V
 -12V
 *F12V
 3A
 0A
 0A
 0A
 30A
 8A
 4A
 4A
 ---
 12A
 ---
 ---
 150W  200W  ±2%
 ±4%
 ±4%
 ±4%
 PU200-44  +5V
 +12V
 -15V
 
*F15V
 3A
 0A
 0A
 0A
 30A
 8A
 4A
 4A
 ---
 12A
 ---
 ---
 150W  200W  ±2%
 ±4%
 ±4%
 ±4%
 PU200-45  +5V
 +12V
 -12V
 
*F24V
 3A
 0A
 0A
 0A
 30A
 8A
 4A
 4A
 ---
 12A
 ---
 ---
 150W  200W  ±2%
 ±4%
 ±4%
 ±4%
 *Ipk is the peak output current with 10% max. duty cycle for less than 60 seconds.
   Total peak power must not exceed 200 watts.
 
*Pmax1 is the maximum total output power at free air convection.
 
*Pmax2 is the maximum total output power at 25 CFM forced air.
 
*Output #4 on quad-ouput models is floating. It can be used as + or - output.