PUP60, PUP80, PUP130 Series        Data Sheet
60-130W Single Output
Desktop AC/DC Power Adapters

Input Voltage.............90 to 130 VAC or 180-260 VAC auto-ranging
Input Frequency...........47 to 63 Hz
Inrush Current............15A@115VAC, 30A@230VAC; @25°C cold start
Ripple & Noise............1% peak to peak max.
Overcurrent Protection....Short circuit protectin on all outputs
Overvoltage Protection....112% to 132% on main output
Operating Temperature.....0-70°C; 100% load up to 50°C
Derating..................Derated 2.5%/°C from 50°C to 70°C 
Cooling...................Convection for PUP60/PUP80;
                          Built-in DC fan for PUP130
Hold-up Time..............15 msec min. @110VAC for PUP60/PUP80;
                          10 msec min. @110VAC for PUP130
Switching Frequency.......60K to 75K Hz
Efficiency................65% min. at full load
Line Regulation...........±0.5% max. at full load
Safety Approvals..........UL 1950, CSA C22.2 No. 234, IEC 950/EN60905
EMI Standards.............FCC Class B, CISPR 22 (EN 55022) Class B
MTBF......................>300,000 hours at full load @25°C
Input Connector...........IEC 320/C14 3-pin male inlet
Output Connector..........8-pin male DIN (Contact factory for other types.)
Power On/Off Switch.......Optional (Suffix S)
Remote Sense..............Standard on PUP60; Optional on PUP80 & PUP130
Weight....................2.4 lb
Dimensions, L*W*H.........7.01*3.74*2.5 inches

 Model No.

Output
 Vnom  Imin  Imax  Pmax  Tol.
 PUP60-10    5V  0A  12A    60W  ±5%
 PUP60-10-1    7V  0A  8.6A    60W  ±5%
 PUP60-11  10V  0A  6A    60W  ±5%
 PUP80-12  12V  0A  6.7A    80W  ±4%
 PUP80-13  15V  0A  5.3A    80W  ±3%
 PUP80-13-1  18V  0A  4.5A    80W  ±3%
 PUP80-14  24V  0A  3.4A    80W  ±3%
 PUP80-16  30V  0A  2.7A    80W  ±2%
 PUP80-17  36V  0A  2.3A    80W  ±2%
 PUP80-18  48V  0A  1.7A    80W  ±2%
 PUP130-12  12V  0A  10.8A  130W  ±5%
 PUP130-13  15V  0A  8.6A  130W  ±4%
 PUP130-13-1  18V  0A  7.2A  130W  ±4%
 PUP130-14  24V  0A  5.4A  130W  ±3%
 PUP130-16  30V  0A  4.3A  130W  ±3%
 PUP130-17  36V  0A  3.6A  130W  ±2%
 PUP130-18  48V  0A  2.7A  130W  ±2%
 NOTES:
 Add suffix "S" to the model # for optional on/off switch.
 For other output connectors, consult factory.

| AC/DC | DC/DC | DC/AC | Medical Power | Contact us | Inquiry |