Input Voltage.............85 to 264 VAC Input Frequency...........47 to 63 Hz Inrush Current............15A@115VAC, 30A@230VAC; @25°C cold start Input Output Isolation....4,000 VAC Leakage Current...........90µA max. @115VAC/60Hz, 150µA max. @230VAC/50Hz Ripple & Noise............1% peak to peak max. Overcurrent Protection....Short circuit protectin on all outputs Overvoltage Protection....112% to 132% on main output Power Fail Detect Signal..TTL logic high for normal operation, TTL logic low upon loss of input power Operating Temperature.....0-70°C; 100% load up to 50°C Derating..................Derated 2.5%/°C from 50°C to 70°C Hold-up Time..............12 msec min. at nominal input Switching Frequency.......20K to 250K Hz, varies with load and line Efficiency................65% min. at full load Line Regulation...........±0.5% max. at full load Safety Approvals..........UL2601-1, CSA C22.2 No. 601.1, TUV EN60601-1/IEC601-1 EMI Standards.............FCC Class B, EN55011 (CISPR 11) Level B MTBF......................>400,000 hours at full load Input Connector...........5-pin/3.96mm pitch, Molex 2878 compatible Output Connector..........13-pin/3.96mm pitch, Molex 2878 compatible Weight....................1.32 lb Dimensions, W*L*H.........4.25*7*1.95 inches
PM110 Series Medically Approved
110W Single to Quad Output
Open Frame AC/DC SwitchersData Sheet
- EN 61000-3-2 Compliance
- UL, CSA & TUV Approved
- CE Marked
- 85 to 264 VAC Universal Input
- 4,000 VAC Isolation
- Low Leakage Current
- Meets Medical EMI Requirements
- Overvoltage & Overcurrent Protections
- Power Fail Detection (PFD)
- 100% Burn-In
- High Reliability
Model No. Output Vnom Imin Imax *Ipk *Pmax1 *Pmax2 Tol. Single Output Models PM110-10-1A 3.3V 0A 22A --- 52W 72W ±3% PM110-10A 5V 0A 22A --- 80W 110W ±3% PM110-12A 12V 0A 9A --- 80W 108W ±2% PM110-13A 15V 0A 7.5A --- 80W 110W ±2% PM110-14A 24V 0A 4.5A --- 80W 108W ±2% PM110-16A 30V 0A 3.6A --- 80W 108W ±2% Dual Output Models PM110-23A +5.1V
+12V0A
0A10A
5A---
9A80W 110W ±3%
±3%Triple Output Models PM110-31A +5.1V
+12V
-12V0A
0A
0A10A
5A
1A---
9A
---80W 110W ±3%
±3%
±4%PM110-32A +5V
+15V
-15V0A
0A
0A10A
4A
1A---
7.5A
---80W 110W ±3%
±3%
±4%Quad Output Models PM110-40A +5.1V
+12V
-12V
-5V0A
0A
0A
0A10A
5A
1A
1A---
9A
---
---80W 110W ±3%
±3%
±4%
±4%PM110-41A +5.1V
+15V
-15V
+24V0A
0A
0A
0A10A
4A
1A
1A---
7.5A
---
---80W 110W ±3%
±3%
±4%
±4%PM110-42A +5.1V
+12V
-12V
+12V0A
0A
0A
0A10A
5A
1A
1A---
9A
---
---80W 110W ±3%
±3%
±4%
±4%PM110-45A +5.1V
+12V
-12V
+24V0A
0A
0A
0A10A
5A
1A
1A---
9A
---
---80W 110W ±3%
±3%
±4%
±4%PM110-45-1A +5.1V
+12V
-12V
+24V2A
0A
0A
1.5A10A
5A
1A
3A---
9A
---
---80W 110W ±3%
±3%
±4%
±10%PM110-45-2A +5.1V
+24V
-12V
+12V0A
0A
0A
0A10A
3A
1A
1A---
5A
---
---80W 110W ±3%
±3%
±4%
±4%PM110-46A +5.1V
+15V
-15V
-5V0A
0A
0A
0A10A
4A
1A
1A---
7.5A
---
---80W 110W ±3%
±3%
±4%
±4%*Ipk is the peak output current with 10% max. duty cycle for less than 60 seconds.
Total peak power must not exceed 130 watts.
*Pmax1 is the maximum total output power at free air convection.
*Pmax2 is the maximum total output power at 25 CFM forced air.Note: Add suffix "B" for L-bracket , "C" for enclosure.